Digital pathology (DP) still lacks a common standard for quality control
(QC), which puts diagnostic accuracy and regulatory compliance at risk. Working
from scanner validation data and AI benchmarks, we assembled a QC system around
five areas: fidelity of acquisition, integrity of image data, completeness of
metadata, reproducibility of computation, and stability over time. Twelve
indicators were quantified, among them focus map CV < 8%, color deviation
ΔE* < 3.2, and hash consistency > 99.9997%. The framework that emerged is
modular and tiered, spanning pre-scan, real-time, and post-conversion checks.
Twelve whole-slide imaging systems drawn from three vendors and four models
were stress-tested; every one degraded under operational load, with focus map
CV rising from 5.1% at baseline to 12.9% under thermal shift and returning to
4.8% after recalibration. An artifact detector built from two parallel
ResNet-18 branches, trained on 14,280 regions of interest from 1,842 clinical
slides, reached 94.6% sensitivity and 97.8% specificity across six artifact
categories. Most slides scored in the low-severity band (66.1%), 8.2% crossed
the review threshold, and human reviewers overrode only 2.1% of those calls.
Detection shortened rejection latency from 4.2 minutes to 18.3 seconds, a
13.8-fold gain in throughput. Metadata completeness varied by institution, from
92.4% at academic centers to 78.9% at community hospitals. Because the design
follows existing regulatory expectations and interoperates with the LIS, it can
be recalibrated continuously rather than replaced.
Keyword
Digital pathology; quality control; slide validation
References
[1] Campanella G, Rajanna AR, Corsale L, Schüffler PJ, Yagi Y, Fuchs TJ, et al. Towards machine learned quality control: a benchmark for sharpness quantification in digital pathology. Comput Med Imaging Graph. 2018;65:142-51.
[2] Wright AI, et al. A point-of-use quality assurance tool for digital pathology remote working. J Pathol Inform. 2020;11(1):17.
[3] Patti R. Development of a deep learning-based method for artifact detection and quality controls in digital pathology [master’s thesis]. Turin, Italy: Politecnico di Torino; 2022.
[4] Ardon O. Quality management in digital pathology: analytic and postanalytic phases. In: Digital Pathology. Academic Press; 2025. p. 103-33.
[5] Schömig-Markiefka B, et al. Quality control stress test for deep learning-based diagnostic model in digital pathology. Mod Pathol. 2021;34(12):2098-108.
[6] Weng Z, et al. GrandQC: a comprehensive solution to quality control problem in digital pathology. Nat Commun. 2024;15(1): 10685.
[7] Kanwal N, López-Pérez M, Kiraz U, Zuiverloon TCM, Molina R, Engan K, et al. Are you sure it’s an artifact? Artifact detection and uncertainty quantification in histological images. Comput Med Imaging Graph. 2024;112:102321.
[8] Jurgas A, Wodzinski M, D’Amato M, van der Laak J, Atzori M, Müller H, et al. Improving quality control of whole slide images by explicit artifact augmentation. Sci Rep. 2024;14(1):17847.
Copyright
© 2026 by the author(s).
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives (CC BY-NC-ND) license, which permits non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not modified or adapted.
https://creativecommons.org/licenses/by-nc-nd/4.0/
How to cite this paper
Pathways for Establishing a Quality Control System for Digital Pathology Slides
How to cite this paper: Yujun Fan. (2026) Pathways for Establishing a Quality Control System for Digital Pathology Slides. International Journal of Clinical and Experimental Medicine Research, 10(5), 372-376.
DOI: http://dx.doi.org/10.26855/ijcemr.2026.09.004